Explanation on the hold time of DS75 2-wire communication SDA

Abstract: The 2-wire communication timing of DS75 is different from the I²C standard. This application note details the differences between the two. The SDA signal is not held internally by the DS75. The bus master keeps the SDA signal until the falling edge of the SCL signal ends.

Preface This application note details the difference between the DS75's 2-wire timing and I²C. In I²C, the SDA signal is delayed by at least 300ns inside the slave, thus allowing simultaneous changes in SCL and SDA levels. However, the DS75 does not delay the SDA signal for the SCL signal, so the bus master must maintain the SDA signal in the correct logic state before the SCL transitions to a logic low level to prevent false triggering of START and STOP operations. Correct timing The SDA line of the DS75 does not have an internal delay for SCL. Therefore, when writing data, the SDA logic level must be maintained outside the DS75 before SCL transitions to a low level. Otherwise, it will be mistaken for a start or stop signal. When writing a logic "1" on a 2-wire bus, it is necessary to ensure that the SCL level is lower than the logic low threshold level VIL before the SDA level drops to a safe logic high threshold level VIH (0.7 x VDD minimum) (0.3 x VDD maximum). When writing logic "0", the SCL level must be lower than VIL before the SDA level rises to VIL. When the START signal is generated, SDA must be below VIL before SCL drops to VIH. When the STOP signal is generated, SDA must be higher than VIH before SCL is reduced to VIH. The VIL and VIH values ​​of each device have been tested in production. To ensure that the entire voltage and temperature range, even if there are device manufacturing tolerances, this timing can run correctly.

figure 1.
figure 1.

figure 2.
Figure 2. Summary The DS75 timings are somewhat different from the I²C standard. DS75 does not delay SDA internally for SCL. Therefore, the system host is required to maintain the SDA level on the falling edge of SCL to prevent the logic "1" from being mistaken for the START signal and the logic "0" to be mistaken for the STOP signal.

Printer Accessories

These printer accessories are include of printer grid, Eliminator,etc.

The cartridge is irradiated by laser beam to adsorb toner, and then the toner is hot pressed by fixing roller for printing. In this process, there will be part of toner residual, which can not be "granules returned to the warehouse"; Automatic cleaning function is not adsorbed new toner particles and directly print, will remain toner away, fully ensure the next printing effect. And the Plate-Grid plays an important role. When high voltage generator to a high voltage electrode, wire electrode with reseau formed between a strong electric field, and release the corona, wire electrode and the photosensitive drum ionizes the air between the air ions migrate to the drum surface, make the photoconductor (drum) surface is full of charge, so can spare toner "adsorption to warehouse", so as to save toner, The purpose of reducing environmental pollution.

Hp Printer Tray,Hp Printer Paper Tray,Usb A Printer Cable,Printer With Paper Tray

SHAOXING HUALI ELECTRONICS CO., LTD. , https://www.cnsxhuali.com