TBEA Xinjiang Power Transmission Technology Industrial Park is the largest UHV transformer production base in western China for Central Asia, South Asia and West Asia. The UHV base project started construction in April 2010 and was put into operation at the end of March 2011. It took only eight months from construction to completion. As a national key industry revitalization and technological renovation project, the workshop adopts world-class standard design with independent intellectual property rights, adopts first-rate manufacturing and testing equipment at home and abroad, and fully integrates advanced automated, unmanned, digital, and integrated production methods. The base's equipment, R&D, production and testing capabilities have reached the world's leading level, providing guarantee for the superior performance and superior quality of UHV transformer products.
The Xinjiang Uygur Autonomous Region Party Committee Standing Committee and Vice-President of the Autonomous Region Kuhesi Maiheti stated at the ribbon-cutting ceremony that the completion of the UHV base of the TBEA Xinjiang Power Transmission Technology Industrial Park and the off-line production of UHV products is to accelerate the advancement of Xinjiang’s advantages. It is of great significance to transform resources, seize the commanding heights of the world's ultra-high voltage power transmission equipment manufacturing industry, and nurture independent innovation and self-development capabilities.
Insulation terminal is low temperature suppress joint on the wire, cable
or electrical equipment.There are many kinds of insulation terminal
name, Insulated Terminals is also known as Cold-Press Terminal, air
connector, etc.It is used to implement a accessories, electrical
connection in the industry we will insulation terminal is classified
into the category of the connector.We may be unfamiliar with insulation
terminal, but when it comes to the connector, that we should be more
familiar with.So in daily life we what to need to pay attention to in
the use of the insulation of the terminals have to know?The dragon
overflow terminal is to introduce the insulation terminal use matters
needing attention.
A, should fully understand to the insulation of
the terminal operation, familiar with the operation method, so as to
ensure the correct operation;For the insulation of the terminal does not
have the wrong operation, should use color code or markup to be
identifiers, or right in front of the connection types are
corresponding, and ensure the mutual connection correct
positioning;Should pay special attention to prevent error with needle
socket inserted, otherwise will damage the insulation terminal, and lead
to accidental electrical contact;Should ensure that the insulation
terminal connection in place, on special occasions is not easy to check,
should be in the corresponding procedures to make detailed rules, and
we can check through the looking glass.
Second, insulated terminal
termination, shall be in strict accordance with the corresponding
termination requirements specification or termination and check, and
according to the corresponding node number termination.Selection of
cable wires between the insulating layer thickness should be matching
with contact element spacing, the cable core should have contact with a
terminal matching, when exposed to a cross between, and lines.
Three, welding should according to the bare wire diameter to select the
corresponding power electric welding each contact time is generally not
more than 5 s, don't let the flux into the insulator should be paid
attention to, lest cause the loss of product insulation resistance.
Four, insulated terminal is in a state of separation should be fitted
with a protective cap or shall adopt other measures for dust;If the
insulation terminal connection are not isolated, for a long time to be
able to play on insurance between plug and socket.
Five, cleaning
insulation terminal, the silk with anhydrous ethanol can be used for,
dry after use.May cause harmful effects in the connector are not allowed
to be used in the chemical solvents such as acetone.
Six, insulated
terminal connection or separation, should try to make the plug and
socket axis line, and the anchorage cable, avoid the plug role by
tangential force, prevent cable sagging cause the damage of the
connector.
Seven, insulated terminal before is not properly connected or completely lock, ban on electricity.
Eight, fixed in insulation terminals, wiring harness, clamping and so
on occasion, use should be threaded connection locking device (locking
screw, locking ring, fuse, etc.).
Nine, acceptance and testing
insulation terminal, should according to the product related standards
and requirements of the specification.Acceptance and inspection has been
used by the electric connector, product related standards and operating
instructions should be reduce the requirements, on the basis of the use
of equipment insulation terminal should be intact, performance
qualified;Probe should conform to the requirements of the standard,
otherwise easy to jack damage.