Mitsubishi PLC multiple output circuit instructions (MPS, MRD, MPP) - Solutions - Huaqiang

SMD aluminum electrolytic capacitor
Brand AVX TPSE226M035R0125 Low impedance tantalum capacitor AVX 22
Electronic scale crystal oscillator 3.2*2.5mm 3225 16M (16.000MHZ) 12PF 10PPM 20PPM 30PPM

Figure 1 multi-output instruction usage map

Precautions for use:

(1) The MPS command can be used to store multiple circuits or electric circuit blocks for subsequent multi-branch output.

(2) Use the MPS push instruction before the first branch, use the MRD stack instruction before the middle branch of the multiple branch, and use the MPP pop instruction for the last branch of the multiple circuit.

(3) The MPP instruction must be used to process the last branch, and the use of MPS and MPP cannot be no more than 11 times, and it must appear in pairs.